There are many different metal flashing shapes but in your case the metal laps over the fascia board perhaps 1 4 inch then is bent at a 90 degree angle to pass over the top of the fascia board then bent again at a 90 degree angle to go up the wall so that it extends behind the first row of vinyl siding.

How much flashing must be behind cement siding and roof.

This gap can get covered over if the home has been roofed over since the siding was installed thus building up the roof height. Bent into an l shape. The step flashing should be visible below the siding because siding installers should leave a 75 to 1 5 inch gap between the siding and the roof below. The solution to rotting sidewalls is a small piece of bent metal called a kickout flashing at roofing suppliers which simply directs all that water away from the wall.

But unlike fiber cement siding wood is almost sure to rot. Flashing a wood framed chimney is like flashing a dormer except there s no roof behind it to direct uphill water away without protection water can leak into the joint and rot your walls. One installe told me he would have to rip it all out which i thought was a bit much if flashing can be inserted somehow or middle panels 1 of 3 layers replaced and flashed on top and bottom. Step flashing is used to provide a water tight connection where roofing adjoins a vertical juncture.

And when those corners start to decay they become. There are a few general best practices you need to know. Posted march 4 2017 filed under roof installation roof repair maintenance. Step flashing is the most time consuming of all flashing jobs on the roof because you must complete it step by step as you shingle up the roof.

First step flashing must be installed before the siding so that the siding can cover the top of the flashing. The question is can those be removed and then flashing slid under the horizontal butt joints in the 4 8 panels. When it comes to flashing siding corners many builders simply use a 1x wood corner. In my opinion some sort of impervious membrane should be installed over the sheathing and behind the flashing both of which should be lapped by the siding and the flashing should have 2 4 inches exposed between the concrete and the siding.

I wish i had an easy answer for you because what you are attempting creates a couple of problems. Even if the roof has been properly flashed against the sidewall this one hasn t water can still run down the side of the house and behind the siding causing rot.

Wall Flashing Roof Wall Flashing Errors And Causes Of Leaks

Wall Flashing Roof Wall Flashing Errors And Causes Of Leaks

How To Flash Siding Butt Joints After The Siding Is Installed Charles Buell Inspections Inc

How To Flash Siding Butt Joints After The Siding Is Installed Charles Buell Inspections Inc

It S Called Kick Out Flashing For A Reason

It S Called Kick Out Flashing For A Reason

Kick Out Flashing When James Hardie Best Practices Aren T Followed

Kick Out Flashing When James Hardie Best Practices Aren T Followed

Source : pinterest.com